USGS

Occurrence of Selected Radionuclides in Ground Water Used for Drinking Water in the United States: A Targeted Reconnaissance Survey, 1998

U.S. Geological Survey Water-Resources Investigations Report 00-4273

 

By Michael J. Focazio, Zoltan Szabo, Thomas F. Kraemer, Ann H. Mullin, Thomas H. Barringer, and Vincent T. dePaul

 

The full report is available in pdf.  Links to the pdf.

CONTENTS

Abstract

Introduction

Purpose and Scope

Acknowledgments

General Background on Radionuclide Chemistry

Existing Sources of Information for Radionuclide Data

Radium in Water Resources of the United States

Occurrence of Radium-224

Occurrence of Radium-226

Occurrence of Radium-228

Other Naturally Occurring Alpha-Particle Emitting Radionuclides

Limitations of Data Sources

Data Collection and Laboratory Analytical Methods

Well Selection

Sample-Collection Methodology

Analytical Methodology

Reporting of Analytical Results and Statistical Calculations with Raw-Data Values

Occurrence of Selected Radionuclides in Ground Water Used as Drinking Water

Radium-224

Radium-226 and Radium-228

Radium Isotope Ratios and Correlations

Polonium-210 and Lead-210

Limitations and Perspective on the Reconnaissance Survey

Analysis of Quality-Control Data

The Effects of a Targeted Sampling Design on Interpretations of Results of the Survey

Cancer Risk Estimates for Radium Isotopes in Drinking Water

Interpretations of Polonium-210 and Lead-210 Data

Implications for Compliance Monitoring

Compliance Monitoring Procedures for Regulated Radionuclides Used by Public Water-Supply Systems and Results of Previous Studies

Limitations in the Current Monitoring Procedures for Alpha-Particle Emitting Radionuclides and the Combined Radium Standard

Conclusions

References Cited

Glossary

Appendix-- Radionuclide Data and Ancillary Information

Abstract

The U.S. Geological Survey, in collaboration with the U.S. Environmental Protection Agency, the American Water Works Association, and the American Water Works Service Company, completed a targeted national reconnaissance survey of selected radionuclides in public ground-water supplies. Radionuclides analyzed included radium-224 (Ra-224), radium-226 (Ra-226), radium-228 (Ra-228), polonium-210 (Po-210) and lead-210 (Pb-210).

This U.S. Geological Survey reconnaissance survey focused intentionally on areas with known or suspected elevated concentrations of radium in ground water to determine if Ra-224 was also present in the areas where other isotopes of radium had previously been detected and to determine the co-occurrence characteristics of the three radium isotopes (Ra-224, Ra-226, and Ra-228) in those areas. Ninety-nine raw-water samples (before water treatment) were collected once over a 6-month period in 1998 and 1999 from wells (94 of which are used for public drinking water) in 27 States and 8 physiographic provinces. Twenty-one of the 99 samples exceeded the current U.S. Environmental Protection Agency drinking-water maximum contaminant level of 5 picocuries per liter (pCi/L) for combined radium (Ra-226 + Ra-228). Concentrations of Ra-224 were reported to exceed 1 pCi/L in 30 percent of the samples collected, with a maximum concentration of 73.6 pCi/L measured in water from a nontransient, noncommunity, public-supply well in Maryland. Radium-224 concentrations generally were higher than those of the other isotopes of radium. About 5 percent of the samples contained concentrations of Ra-224 greater than 10 pCi/L, whereas only 2 percent exceeded 10 pCi/L for either Ra-226 or Ra-228. Concentrations of Ra-226 greater than 1 pCi/L were reported in 33 percent of the samples, with a maximum concentration of 16.9 pCi/L measured in water from a public-supply well in Iowa. Concentrations of Ra-228 greater than 1 pCi/L were reported in 22 samples, with a maximum concentration of 72.3 pCi/L measured in water from a non-transient, noncommunity, public-supply well in Maryland.

Radium-224, which is a decay product of Ra-228 in the Th-232 decay series, was significantly correlated with Ra-228 (Spearman’s rank correlation coefficient “r” equals 0.82) and to a lesser degree with Ra-226 (r equals 0.69), which is an isotope in the U-238 decay series. The rank correlation coefficient between Ra-226 and Ra-228 was 0.63. The high correlation between Ra-224 and Ra-228 concentrations and the corresponding isotopic ratios of the two (about 1:1 in 90 percent of the samples) indicates that the two radionuclides occur in approximately equal concentrations in most ground water sampled. Thus, Ra-228 can be considered as a reasonable proxy indicator for the occurrence of Ra-224 in ground water.

The maximum concentration of Po-210 was 4.85 pCi/L and exceeded 1 pCi/L in only two samples. The maximum concentration of Pb-210 was 4.14 pCi/L, and about 10 percent of the samples exceeded 1 pCi/L. Areas with known, or suspected, elevated concentrations of polonium and lead were not targeted in this survey.

Three major implications are drawn for future radionuclide monitoring on the basis of this information: (1) grossalpha particle analyses of ground water should be done within about 48–72 hours after collection to determine the presence of the short-lived, alpha-particle emitting isotopes, such as Ra-224, which was detected in elevated concentrations in many of the samples collected for this survey; (2) the isotope ratios of Ra-224 to Ra-228 in ground water are variable on a national scale, but the two radioisotopes generally occur in ratios near 1:1, therefore, the more commonly measured Ra-228 can be used as an indicator of Ra-224 occurrence for some general purposes other than compliance; and (3) the isotopic ratios of Ra-226 to Ra-228 were less than 3:2 in many samples. These ratios corroborate results of previous studies that have shown the presence of Ra-228 (a beta-particle emitter) can cause a flaw in conventional radium compliance monitoring when the gross-alpha particle screen indicates no need for further analysis (the gross alpha particle activity is less than 5 pCi/L) even though the ratio of Ra-226 to Ra-228 is less than 3:2.

 


The text and graphics are presented here in pdf format (print quality):

The full report is 1.5MB


The report is also available in sections in pdf for a faster download:

 

If you have Adobe Acrobat Reader installed on your computer, you may view and/or print the PDF version of this report. If you do not have Acrobat Reader, you may download it here.

 

Users with visual disabilities can visit this site for conversion tools and information to help make PDF files accessible.


For additional information write to:
U.S. Geological Survey
Office of Ground Water
Mail Stop 411
12201 Sunrise Valley Drive
Reston, VA 20192
Copies of this report may be purchased from:
U.S. Geological Survey
Branch of Information Services
Box 25286, Mail Stop 417
Denver Federal Center
Denver, CO 80225-0286


FirstGov button  Take Pride in America button